A
heavy duty rectangular rack and panel line to line connector with low insertion and
withdrawal forces. It is particularly suited for use in rugged conditions, the standard
barrier polarized style being available in either Nylon Phenolic for normal environments,
or Diallyl-Phthalate (DAP) for more severe environments.
|
| Insulator | Nylon PF or Diallyl-phthalate (DAP) |
| Contact | Copper alloy plated hard acid gold |
| Mounting plates | Stainless steel |
| Latching screws & bushes | Mild steel bright nickel plate |
| Dowels | Brass nickel plate |
| Covers | Aluminum |
| Current | NYLON PF | D.A.P. |
| All contacts simultaneously | at 80°C Tamb. 5A max. | at 100°C Tamb. 5A max. |
| Working Voltage | 800Vd.c. or a.c. peak | 800Vd.c. or a.c. peak |
| Proof Voltage | 3.5kVd.c. or a.c. peak | 3.5kVd.c. or a.c. peak |
| Contact Resistance (initially) | 5mohm max. | 5mohm max. |
| (after conditioning) | 10mohm max. | 10mohm max. |
| Insulation Resistance (initially) | 105Mohm min. | 107Mohm min. |
| (after conditioning) | 104Mohm min. | 106Mohm min. |
| Mechanical operations | 500 | 500 |
| Insertion and withdrawal forces (contact pair) | 2.25N max./0.75 min. | 2.25N max./0.75 min. |
| Climatic category | 40/100/21 | 55/125/56 |
DESCRIPTION |
||||||||||||
|
ORDERING CODE |
||||||||||
|
*Sockets are normally supplied with floating bushes to assist alignment when mounted on
racks and chasis. For sockets without floating bushes - add P to end of order code e.g.
Order code RS24P.
![]()